IC Design Occupational Safety and Health Management
Technical Research Report on Occupational Safety and Health Management for IC Design Companies
IC 設計公司職業安全衛生管理技術研究報告
Scope: Taiwan-based IC design companies, including offices, chip validation laboratories, server rooms, outsourced activities and contractor operations.
研究範圍:台灣 IC 設計公司之辦公場所、晶片驗證實驗室、伺服器機房、委外及承攬作業。
Source review date: November 14, 2026.
資料查核日期:2026 年 11 月 14 日。
Report basis: This report draws on official regulations and technical guidance. It does not include company-specific site inspections, exposure measurements or incident data. Proposed priorities, indicators and implementation schedules are management recommendations rather than statutory requirements.
報告基礎:本報告依據官方法規及技術指引編製,尚未納入特定公司的現場勘查、暴露量測及事故資料。提出之改善優先序、績效指標與導入時程屬管理建議,並非法定要求。
Chapter 1. Executive Summary
第一章 執行摘要
Occupational safety and health management in IC design companies should address both cumulative health risks and acute accident risks. Prolonged computer work, project pressure and night work can create sustained health burdens, while chip validation, power testing, equipment maintenance and contractor activities can introduce immediate physical hazards.
IC 設計公司的職業安全衛生管理,應同時處理累積性健康風險與急性事故風險。長時間電腦作業、專案壓力及夜間工作可能形成持續性健康負荷;晶片驗證、電源測試、設備維修及承攬作業則可能帶來立即性的實體危害。
A fabless business model does not establish that a workplace is low risk. Companies developing power management ICs, high-performance computing devices, optical interfaces or battery-related products may operate laboratories containing hazardous voltage, high current, stored energy, lasers or chemicals.
無晶圓廠的經營模式,不代表工作場所必然屬於低風險。開發電源管理 IC、高效能運算元件、光通訊介面或電池相關產品的公司,可能設置具有危險電壓、大電流、儲能、雷射或化學品的實驗室。
The recommended management priorities are to identify hazards by actual activity, integrate safety into test development, manage workload during project peaks, verify critical protective functions and assign clear ownership for corrective actions.
建議管理重點為:依實際活動辨識危害、將安全納入測試開發、管理專案高峰期工作負荷、驗證關鍵防護功能,以及明確指定改善措施的責任人。
| Priority | Management objective |
| Activity-based risk assessment 依作業進行風險評估 |
Assess office work, validation, rework, maintenance and special analysis separately. 分別評估辦公、驗證、返修、維修及特殊分析作業。 |
| Safety in test design 測試設計安全 |
Review new boards, fixtures and automated tests before operation. 新板卡、治具及自動化測試上線前完成安全審查。 |
| Workload management 工作負荷管理 |
Plan staffing, recovery time and escalation arrangements during critical milestones. 重大里程碑期間預先安排人力、休息及問題升級機制。 |
| Protective-function verification 防護功能驗證 |
Test interlocks, thermal protection, extraction and energy isolation. 測試連鎖、過溫保護、排氣及能源隔離。 |
| Accountable corrective action 具責任歸屬的改善 |
Assign an owner, deadline and acceptance evidence to each action. 每項措施指定責任人、期限及驗收證據。 |
Chapter 2. Industry Characteristics and Study Boundaries
第二章 產業特性與研究邊界
Risk classification should reflect the work actually performed. Company names, product categories and the absence of wafer fabrication are insufficient grounds for determining occupational risk.
風險分類應反映實際執行的工作。公司名稱、產品類別及是否具有晶圓製造活動,都不足以單獨判定職業風險。
| Area or activity 區域或活動 |
Typical work 常見工作 |
Principal hazards 主要危害 |
| Design offices 設計辦公區 |
RTL, verification, analog design, physical design and software development RTL、驗證、類比設計、實體設計及軟體開發 |
Musculoskeletal strain, visual fatigue, prolonged sitting and psychosocial stress 肌肉骨骼負荷、視覺疲勞、久坐及心理社會壓力 |
| Chip validation laboratories 晶片驗證實驗室 |
Bring-up, functional testing, performance and power measurements 初始啟動、功能測試、效能及功耗量測 |
Electric shock, short circuits, overheating and fixture failure 感電、短路、過熱及治具失效 |
| Power electronics laboratories 電力電子實驗室 |
PMIC, motor-driver and SiC/GaN application testing PMIC、馬達驅動器及 SiC/GaN 應用測試 |
Hazardous voltage, high current, stored energy and component rupture 危險電壓、大電流、儲能及元件爆裂 |
| Board rework areas 板卡返修區 |
Soldering, hot-air rework and cleaning 焊接、熱風返修及清潔 |
Solder fume, burns, solvent exposure and ignition 焊煙、燙傷、溶劑暴露及起火 |
| Reliability testing areas 可靠度測試區 |
Temperature cycling and extended powered testing 溫度循環及長時間通電測試 |
Thermal contact injuries, thermal runaway and unattended faults 高低溫接觸傷害、熱失控及無人值守異常 |
| RF and optical laboratories 射頻與光電實驗室 |
RF, antenna, optical transceiver and laser testing 射頻、天線、光收發器及雷射測試 |
Exposure dependent on accessible emission and operating conditions 依可接觸輻射及操作條件判定暴露 |
| Failure analysis laboratories 失效分析實驗室 |
Decapsulation, sectioning and X-ray inspection 開封、切片及 X 光檢測 |
Chemicals, dust, mechanical hazards and ionizing radiation, where present 實際設置時可能涉及化學品、粉塵、機械及游離輻射 |
| EDA/AI server rooms EDA/AI 機房 |
Server, UPS, electrical and cooling maintenance 伺服器、UPS、配電及冷卻維護 |
Electrical hazards, batteries, manual handling, noise and leaks 電氣、電池、搬運、噪音及洩漏 |
| Contractor and off-site work 承攬與外派作業 |
Renovation, installation and customer-site debugging 裝修、安裝及客戶端除錯 |
Simultaneous operations, isolation failures and unfamiliar environments 交叉作業、隔離失效及陌生環境 |
Fully outsourced wafer fabrication, packaging and production testing should not automatically be described as exposures within the design company’s premises. Supplier-site assignments and contracted activities require separate assessment of work conditions and responsibilities.
完全委外的晶圓製造、封裝及量產測試,不應自動列為設計公司場所內的暴露。供應商現場派駐及承攬活動,應另行評估工作條件與責任界面。
Chapter 3. Taiwan Regulatory and Management Framework
第三章 台灣法規與管理架構
Taiwan’s Occupational Safety and Health Act generally applies across industries. Employers must adopt reasonably practicable preventive measures; office-based operations do not automatically remove these duties. Requirements for safety personnel, health services, training and monitoring must be determined from the applicable business classification, workforce and activities. [1]
台灣《職業安全衛生法》原則上適用於各業。雇主應在合理可行範圍內採取必要預防措施;辦公型態不會自動免除相關義務。安全衛生人員、健康服務、教育訓練及監測要求,應依適用的事業分類、人數與活動判定。[1]
The official implementation guidance reviewed for this report states that the relevant 2025 amendments took effect on July 1, 2026, addressing matters including workplace bullying prevention, prevention at source and contractor management. Certain supporting provisions have separate transition arrangements. A compliance register should therefore record applicable provisions, effective dates and transition deadlines. [2]
本報告查核的官方施行說明指出,2025 年修正之相關條文已於 2026 年 7 月 1 日施行,涉及職場霸凌防治、源頭預防及承攬管理等事項。部分配套規定另有過渡安排,因此法規清單應記錄適用條文、生效日期及緩衝期限。[2]
| Management area 管理面向 |
Applicability review 適用性審查 |
Required management evidence 管理證據 |
| Organization and staffing 組織與人員 |
Business classification, workforce and staffing requirements 事業分類、人數及人員配置要求 |
Assessment, qualifications and appointments 判定紀錄、資格及任命 |
| Health protection 健康保護 |
Examinations, health services and special work conditions 健康檢查、健康服務及特殊作業條件 |
Implementation and follow-up records 執行及追蹤紀錄 |
| Ergonomics and workload 人因與工作負荷 |
Repetitive work, night work and prolonged working hours 重複作業、夜間及長時間工作 |
Assessments, interventions and effectiveness reviews 評估、改善及成效檢視 |
| Workplace misconduct and bullying 職場不法侵害及霸凌 |
Prevention, complaints, investigation and protection 預防、申訴、調查及保護 |
Procedures, training and confidential case records 程序、訓練及保密案件紀錄 |
| Laboratory safety 實驗室安全 |
Electrical, mechanical, thermal and other energy hazards 電氣、機械、熱及其他能源危害 |
Procedures, inspections and maintenance 程序、檢查及維修 |
| Chemicals 化學品 |
Labeling, SDS and exposure-related requirements 標示、SDS 及暴露相關要求 |
Inventory, assessment and monitoring where applicable 清冊、評估及適用時的監測 |
| Contractors 承攬 |
Hazard communication, coordination and responsibilities 危害告知、協調及責任 |
Contracts, permits and handover records 承攬文件、許可及交接紀錄 |
| Special facilities 特殊設施 |
Radiation, gases and other regulated equipment 輻射、氣體及其他受管制設備 |
Applicability assessments and permits where required 適用性評估及依法所需許可 |
International guidance cited in this report supports technical evaluation. It does not replace Taiwan’s legal requirements.
本報告引用的國際指引用於支持技術評估,不取代台灣法規要求。
Chapter 4. Hazard Identification and Risk Assessment
第四章 危害辨識與風險評估
The assessment unit should be a defined task and its credible hazardous events, rather than an equipment name alone. Assessments should include normal operation, board changes, troubleshooting, maintenance, unattended testing and emergencies.
評估單位應為明確作業及其合理可預見的危害事件,而非只有設備名稱。評估範圍應涵蓋正常操作、換板、故障排除、維修、無人值守測試及緊急情境。
Severity and likelihood matrices can support prioritization, but numerical scores should not obscure potentially fatal hazards. Accessible hazardous voltage or missing critical protection requires prompt attention even if no previous accident has occurred.
嚴重度與可能性矩陣可協助排序,但數值分數不應掩蓋可能致命的危害。即使過去沒有事故,可接觸的危險電壓或關鍵防護缺失仍需優先處理。
| Assessment field 評估欄位 |
Required information 必要資訊 |
| Task and scenario 作業與情境 |
Purpose, sequence and normal or abnormal operating modes 目的、步驟及正常或異常運轉模式 |
| Hazard source 危害來源 |
Voltage, current, stored energy, heat, chemicals or other sources 電壓、電流、儲能、熱、化學品或其他來源 |
| Hazardous event 危害事件 |
Contact, short circuit, release, inhalation or entrapment 接觸、短路、逸散、吸入或夾困 |
| Exposed persons 暴露人員 |
Operators, nearby workers, cleaners and maintenance personnel 操作者、鄰近人員、清潔及維修人員 |
| Existing protection 既有防護 |
Enclosures, interlocks, extraction, restrictions and training 外罩、連鎖、排氣、限制及訓練 |
| Verification 驗證方式 |
Measurements, functional testing, observation and document review 量測、功能測試、現場觀察及文件審查 |
| Residual risk 剩餘風險 |
Remaining restrictions and acceptance conditions 仍需採取的限制與接受條件 |
| Action closure 改善結案 |
Owner, deadline, acceptance evidence and review date 責任人、期限、驗收證據及複查日期 |
Chapter 5. Electrical Testing and Energy Isolation
第五章 電氣測試與能源隔離
OSHA identifies electric shock, fire and explosion among electrical hazards in semiconductor operations. Its guidance emphasizes energy-source identification, correct installation, energy control and electrical safety programs. [6]
美國 OSHA 將感電、火災及爆炸列為半導體作業中的電氣危害,並強調能源來源辨識、正確安裝、能源控制及電氣安全管理。[6]
Prototype equipment deserves particular attention because testing may begin before enclosures, wiring arrangements and protective functions are fully developed.
原型設備尤其需要注意,因為測試可能在外罩、接線配置及防護功能尚未完整建立前就已開始。
| Control area 控制面向 |
Recommended practice 建議作法 |
| Contact prevention 接觸防止 |
Use touch-protected terminals, insulation and enclosed fixtures. 使用防觸及端子、絕緣及封閉治具。 |
| Fault protection 故障保護 |
Coordinate current, temperature and fault protection with the source, wiring and load. 依電源、配線及負載協調過電流、過溫與故障保護。 |
| Grounding 接地 |
Review protective, measurement and ESD grounding separately. 分別審查保護、量測及 ESD 接地。 |
| Instrument selection 儀器選用 |
Verify voltage rating, measurement category and common-mode capability. 確認額定電壓、量測類別及共模能力。 |
| Configuration changes 配置變更 |
Reassess protection after circuit or fixture changes. 電路或治具變更後重新評估防護。 |
| Energized diagnostics 帶電診斷 |
Restrict work to assessed tasks and authorized, competent personnel. 限於經評估的作業及經授權、具能力的人員。 |
ESD controls protect components from electrostatic damage; they do not establish protection against electric shock.
ESD 控制用於保護元件免受靜電損傷,不能據此認定人員已獲得感電防護。
Software stop commands, emergency stops and power-button operation do not establish electrical isolation. Maintenance planning must identify utility power, UPS supplies, external supplies, batteries, capacitors and possible backfeed.
軟體停止命令、急停及電源按鈕操作,不代表電氣隔離已完成。維修規劃須辨識市電、UPS、外接電源、電池、電容及可能的逆送電。
Article 254 of Taiwan’s Occupational Safety and Health Facilities Regulations addresses measures for relevant de-energized work, including prevention of unintended energization, residual-charge treatment and verification. Equipment-specific procedures should be developed and implemented by competent personnel. [5]
台灣《職業安全衛生設施規則》第 254 條對相關停電作業規範防止誤送電、殘留電荷處理及確認等措施。應由具能力的人員制定並執行適用於個別設備的程序。[5]
Chapter 6. Extended Powered Testing, Batteries and Thermal Safety
第六章 長時間通電、電池與熱安全
Extended validation depends on software, power supplies, loads and cooling systems operating together. Safety review should establish how the equipment responds to software failure, network loss, sensor failure and cooling interruption.
長時間驗證仰賴軟體、電源、負載及冷卻系統共同運作。安全審查應確認設備在軟體失效、網路中斷、感測器故障及冷卻中斷時的反應。
| Failure scenario 失效情境 |
Recommended control 建議控制 |
Verification focus 驗證重點 |
| Device-under-test short circuit 受測元件短路 |
Current limiting, protective devices and containment 限流、保護裝置及防護外罩 |
Effective fault interruption 有效切斷故障 |
| Rising temperature 溫度持續上升 |
Independent overtemperature protection 獨立過溫保護 |
Operation despite main-program failure 主程式失效時仍可作用 |
| Cooling failure 冷卻失效 |
Cooling-status detection and shutdown logic 冷卻狀態偵測及停機邏輯 |
Safe response to simulated failure 模擬失效後安全反應 |
| Communication loss 通訊中斷 |
Local protection and defined loss-of-connection behavior 本地保護及明確失聯策略 |
Protection remains active 保護持續有效 |
| Battery abnormality 電池異常 |
Dedicated test arrangements and limits on test energy and sample quantity 專用測試安排及測試能量、樣品數限制 |
Isolation, detection and response readiness 隔離、偵測及應變準備 |
| Unattended operation 無人值守運轉 |
Formal eligibility and alarm-response arrangements 正式准入條件及警報應變安排 |
Alarms are received and acted upon 警報能被接收並處理 |
Unattended operation should be an approved operating mode. Schedule pressure should not substitute for verification of protective functions.
無人值守運轉應列為經核准的操作模式。排程壓力不能取代防護功能驗證。
Chapter 7. Soldering, Chemicals and Local Exhaust Ventilation
第七章 焊接、化學品與局部排氣
Lead-free solder does not eliminate inhalation hazards. HSE identifies rosin-based solder-flux fume as a cause of occupational asthma and recommends exposure control and maintenance of extraction systems. [7]
無鉛焊料不會消除吸入危害。英國 HSE 指出,含松香助焊劑焊煙可能造成職業性氣喘,並建議控制暴露及維護抽氣系統。[7]
| Management element 管理要素 |
Recommended practice 建議作法 |
| Chemical inventory 化學品清冊 |
Include cleaners, fluxes, adhesives, thermal compounds and trial materials. 納入清潔劑、助焊劑、黏著劑、散熱材料及試用品。 |
| Substitution 替代 |
Evaluate lower-hazard options and assess any new risks. 評估低危害替代方案及其新增風險。 |
| Source capture 源頭捕集 |
Capture emissions near generation and away from the breathing zone. 在產生源附近捕集,避免污染物經過呼吸帶。 |
| Ventilation verification 排氣驗證 |
Check capture performance, maintenance and filter replacement. 確認捕集效果、維護及濾材更換。 |
| Flammable liquids 易燃液體 |
Limit bench quantities and separate them from ignition sources. 限制工作台存量並遠離火源。 |
| Hygiene 衛生 |
Prohibit eating in handling areas and provide appropriate cleaning practices. 禁止在操作區飲食並建立適當清潔措施。 |
| Waste management 廢棄物管理 |
Segregate solder waste, contaminated wipes and waste liquids. 分類收集焊接廢棄物、污染擦拭物及廢液。 |
A circulation fan moves contaminants but does not demonstrate effective extraction. Personal protective equipment should address residual exposure after appropriate source controls.
循環風扇可移動污染物,但不能證明具有有效排氣功能。個人防護具應用於適當源頭控制後仍存在的暴露。
The need for workplace monitoring and special health examinations should be determined from the actual substances, tasks and applicable rules. Small research quantities alone do not justify exclusion.
是否需要作業環境監測及特殊健康檢查,應依實際物質、作業與適用規定判定,不能僅以研發用量少為由排除。
Chapter 8. Ergonomics and the Office Environment
第八章 人因工程與辦公環境
Design engineers may spend prolonged periods using multiple displays and input devices. Laboratory personnel may sustain awkward postures while using microscopes, probing boards or adjusting instruments. Taiwan’s ergonomic prevention guidance provides a framework for identifying and improving such tasks. [4]
設計工程師可能長時間使用多螢幕及輸入設備;實驗室人員則可能在使用顯微鏡、探測板卡或調整儀器時維持不良姿勢。台灣人因性危害預防指引提供了辨識與改善此類作業的架構。[4]
| Issue 問題 |
Recommended intervention 建議改善 |
Effectiveness check 成效確認 |
| Repeated head turning 反覆轉頭 |
Position displays according to use frequency. 依使用頻率配置螢幕。 |
Posture and discomfort review 姿勢及不適檢視 |
| Excessive reaching for a mouse 滑鼠距離過遠 |
Reposition input devices and support the forearms. 調整輸入設備並提供前臂支撐。 |
Shoulder elevation and reach 肩部抬高及伸手情形 |
| Prolonged laptop use 長時間使用筆電 |
Provide suitable display elevation and external input devices. 提供適當螢幕高度及外接輸入設備。 |
Neck and wrist position 頸部及手腕姿勢 |
| Microscope work 顯微鏡作業 |
Adjust eyepieces, seating and work height. 調整目鏡、座椅及工作高度。 |
Neck and shoulder loading 頸肩負荷 |
| Equipment handling 設備搬運 |
Use carts, lifting aids and adequate staffing. 使用推車、升降輔具及適當人力。 |
Route and handling method 路徑及搬運方式 |
| Static posture 固定姿勢 |
Introduce task variation, posture changes and recovery opportunities. 安排任務變化、姿勢變換及休息機會。 |
Actual implementation 實際執行情況 |
Lighting should support both screen work and precision tasks while controlling glare and reflections. Ventilation and indoor environmental concerns should be evaluated using site conditions, complaints and measurements where appropriate.
照明應同時支援螢幕與精密作業,並控制眩光及反射。通風與室內環境問題,應依現場條件、反映事項及必要量測進行評估。
Chapter 9. Workload, Mental Health and Workplace Bullying Prevention
第九章 工作負荷、心理健康與職場霸凌防治
Tape-out, major design changes, first-silicon validation and customer failures can create night work, extended hours and continuous on-call duties. Taiwan’s abnormal-workload prevention guidance addresses risks associated with shift work, night work and prolonged working hours. [3]
Tape-out、重大設計變更、首顆晶片驗證及客戶端故障,可能造成夜間工作、長工時及持續待命。台灣異常工作負荷預防指引涵蓋輪班、夜間及長時間工作相關風險。[3]
| Management level 管理層次 |
Recommended measures 建議措施 |
| Project planning 專案規劃 |
Estimate peak workload, backup staffing and cross-time-zone support needs. 估算高峰工作量、備援人力及跨時區支援需求。 |
| Operational monitoring 執行監測 |
Review actual hours, repeated night work, insufficient recovery and employee feedback. 檢視實際工時、反覆夜間工作、休息不足及員工回饋。 |
| Individual support 個別支持 |
Arrange appropriate professional assessment, work adjustment and follow-up. 安排適當專業評估、工作調整及追蹤。 |
Post-project reviews should investigate the causes of excessive workload, including unstable requirements, inadequate validation resources and poorly defined customer-support responsibilities.
專案結束後,應調查過度工作負荷的原因,包括需求不穩定、驗證資源不足及客戶支援責任不清。
Workplace bullying prevention should include accessible complaint channels, impartial investigation, confidentiality and protection against retaliation, consistent with applicable requirements. Taiwan’s 2026 implementation framework includes specific workplace bullying prevention provisions. [2]
職場霸凌防治應依適用規定,建立可使用的申訴管道、公正調查、保密及防止報復機制。台灣 2026 年施行架構已納入職場霸凌防治相關規定。[2]
Access to health information should be restricted. Managers generally need relevant work limitations and adjustment recommendations rather than complete medical records. Aggregated information should be used for departmental analysis.
健康資訊應限制存取。主管通常需要的是相關工作限制及調整建議,而非完整病歷。部門分析應使用彙整資訊。
Chapter 10. Special Laboratories and Server-Room Safety
第十章 特殊實驗室與機房安全
The following controls apply only where the corresponding equipment or activity is present. Risk should be assessed from accessible energy, emissions and actual operating conditions.
下列控制僅適用於實際設置對應設備或執行相關活動的場所。風險應依可接觸能量、輻射及實際操作條件評估。
| Facility or equipment 設施或設備 |
Management focus 管理重點 |
| Lasers and optical transceivers 雷射與光收發器 |
Identify wavelength, power and accessible beam paths; provide suitable enclosure and interlocks. 辨識波長、功率及可接觸光路,設置適當外罩與連鎖。 |
| RF testing 射頻測試 |
Assess power, frequency, distance and shielding conditions. 評估功率、頻率、距離及屏蔽條件。 |
| X-ray inspection X 光檢測 |
Verify regulatory applicability, shielding, interlocks and personnel requirements. 確認法規適用性、屏蔽、連鎖及人員要求。 |
| Nitrogen and other gases 氮氣及其他氣體 |
Secure containers and assess regulators, piping, leaks and oxygen-deficiency potential. 固定容器,評估調壓器、管路、洩漏及缺氧可能性。 |
| Thermal equipment 高低溫設備 |
Control contact hazards, condensation, icing and safe opening conditions. 控制接觸危害、冷凝、結霜及安全開啟條件。 |
| EDA/AI server rooms EDA/AI 機房 |
Manage distribution, UPS, rack stability, handling and cooling maintenance. 管理配電、UPS、機櫃穩定、搬運及冷卻維修。 |
| Chemical failure analysis 化學失效分析 |
Provide suitable facilities, compatibility assessment, extraction and waste controls. 提供適當設施、相容性評估、排氣及廢棄物控制。 |
Low-power enclosed equipment should not be treated as equivalent to an open high-power system. Conversely, a familiar product category should not be assumed safe without examining its operating configuration.
低功率封閉設備不應與開放式高功率系統視為相同風險;同樣地,也不能因產品類別熟悉,就未檢視操作配置而直接認定安全。
Chapter 11. Contractor, Off-Site and Change Management
第十一章 承攬、外派與變更管理
Renovation, electrical expansion, server-room maintenance and laboratory relocation can introduce new hazards into an occupied workplace. Responsibilities must be explicit when company personnel, building management and contractors work together.
裝修、配電擴充、機房維修及實驗室搬遷,可能在持續使用的場所中引入新危害。公司人員、大樓管理單位與承攬商共同作業時,責任必須明確。
| Stage 階段 |
Required management information 必要管理資訊 |
| Before work 作業前 |
Scope, hazards, competence, isolation ownership, permits and emergency contacts 範圍、危害、能力、隔離責任、許可及緊急聯絡 |
| During work 作業中 |
Simultaneous operations, access, permit conditions and temporary changes 交叉作業、進出、許可條件及臨時變更 |
| After work 作業後 |
Tool accountability, restoration, functional testing and named handover 工具清點、防護復歸、功能測試及具名交接 |
Before off-site assignments, engineers should receive the host facility’s entry requirements, work restrictions and incident-reporting contacts. IC design expertise does not automatically qualify a person to operate unfamiliar production or utility equipment.
工程師外派前,應取得接待場所的入場要求、作業限制及事故通報窗口。具備 IC 設計專業,不代表自動具備操作陌生生產或公用設備的資格。
Changes that should trigger reassessment include higher voltage or current, increased stored energy, new chemicals, altered interlocks, modified ventilation, unattended operation and laboratory or server-room reconfiguration.
建議觸發重新評估的變更,包括提高電壓或電流、增加儲能、使用新化學品、修改連鎖、調整通風、改為無人值守,以及重新配置實驗室或機房。
Chapter 12. Emergency Response and Restart Authorization
第十二章 緊急應變與復機核准
Emergency procedures should reflect actual hazards and be coordinated with building management, emergency responders and relevant equipment suppliers. Personnel should understand the limits of their training and authority.
緊急程序應反映實際危害,並與大樓管理單位、緊急應變機構及相關設備供應商協調。人員應了解自身訓練與權限的界限。
| Scenario 情境 |
Response priorities 應變重點 |
| Electric shock 感電 |
Avoid contact with an energized casualty; isolate safely and activate emergency assistance. 避免接觸仍帶電的傷者,安全隔離並啟動緊急救援。 |
| Equipment smoke or fire 設備冒煙或火災 |
Raise the alarm, evacuate and follow the established response plan. 發出警報、撤離並依既定應變計畫處理。 |
| Battery smoke or abnormal heating 電池冒煙或異常升溫 |
Isolate the area, evacuate and involve appropriate responders. 隔離區域、撤離並交由適當應變人員處理。 |
| Chemical release 化學品洩漏 |
Assess substance and scale; evacuate when beyond trained response capability. 依物質及規模評估,超出訓練能力時撤離。 |
| Gas or oxygen-deficiency alarm 氣體或缺氧警報 |
Evacuate and prevent untrained rescue entry. 撤離並防止未受訓人員進入救援。 |
| Earthquake 地震 |
Protect personnel, then inspect equipment, racks, gases and electrical systems. 先保護人員,再檢查設備、機櫃、氣體及電氣系統。 |
Restart should require confirmation that hazards are controlled, protective functions are verified, necessary inspections are complete and the designated authority has approved operation. Restoration of electricity alone is not sufficient.
復機應確認危害已受控制、防護功能完成驗證、必要檢查完成,並取得指定權責人員核准。僅恢復供電並不足以作為復機條件。
Chapter 13. Responsibilities, Documentation and Performance Indicators
第十三章 責任、文件與績效指標
Senior management should provide resources and decision authority. Safety personnel support the management system and verification, while engineering and laboratory managers retain responsibility for the work they control. Human resources, facilities, IT and occupational health personnel contribute within their functions.
高階管理階層應提供資源與決策權限。職安衛人員協助制度及查核,工程與實驗室主管則對其管理的工作負責。人資、設施、資訊及職業健康人員依職掌參與。
Core documentation should include risk registers, equipment acceptance records, operating and isolation procedures, chemical inventories, health-risk prevention records, contractor controls, change reviews, emergency plans and incident investigations.
核心文件應包括風險清冊、設備准入紀錄、操作及隔離程序、化學品清冊、健康危害預防紀錄、承攬管理、變更審查、應變計畫及事件調查。
| Indicator 指標 |
Suggested definition 建議定義 |
| Overdue high-risk actions 高風險改善逾期數 |
High-risk actions past their approved completion date without acceptance. 超過核定期限且尚未驗收的高風險措施。 |
| Protective-function test completion 防護功能測試完成率 |
Completed required tests divided by tests due. 已完成應辦測試數除以應測試數。 |
| Protective-function failures 防護功能失效數 |
Failures identified during testing or operation, with resolution status. 測試或運轉發現的失效,並列改善狀態。 |
| Pre-operation equipment review 設備上線前審查率 |
New equipment reviewed before use divided by new equipment introduced. 使用前完成審查的新設備除以新增設備。 |
| Workload action completion 工作負荷改善完成率 |
Implemented and confirmed actions divided by actions due. 已執行並確認的措施除以應完成措施。 |
| Ergonomic follow-up 人因改善追蹤率 |
Completed reassessments divided by reassessments due. 已完成複查案件除以應複查案件。 |
| Contractor-action closure 承攬改善結案率 |
Accepted corrective actions divided by actions due. 已驗收改善項目除以應改善項目。 |
| Recurrence 重複發生情形 |
Repeated events with similar causes and associated control failures. 相似原因事件再發及相關控制失效情形。 |
Low reporting volume should not automatically be rewarded. Increased reporting during early implementation may indicate greater willingness to disclose hazards.
不應自動獎勵低通報件數。制度導入初期通報增加,可能表示人員更願意揭露危害。
Chapter 14. Recommended Implementation Roadmap
第十四章 建議導入路線圖
The following schedule is a planning proposal, not a statutory deadline. Immediate serious hazards should be addressed without waiting for a scheduled phase.
下列時程屬規劃建議,並非法定期限。立即性重大危害應直接處理,不應等待排定階段。
| Phase 階段 |
Main activities 主要工作 |
Acceptance evidence 驗收證據 |
| Days 1–30 第 1–30 天 |
Inventory workplaces, personnel, equipment and activities; identify major gaps. 盤點場所、人員、設備及活動,辨識重大缺口。 |
Risk register, applicability register and immediate-action list 風險清冊、適用性清單及立即改善清單 |
| Days 31–60 第 31–60 天 |
Improve hazardous testing, extraction and isolation; establish critical procedures. 改善高危害測試、排氣及隔離,建立關鍵程序。 |
Test results, procedures and authorization records 測試結果、程序及授權紀錄 |
| Days 61–90 第 61–90 天 |
Implement ergonomics, workload, contractor and emergency measures. 推動人因、工作負荷、承攬及應變措施。 |
Intervention records, drills and corrective-action tracking 改善紀錄、演練及缺失追蹤 |
| Months 4–6 第 4–6 個月 |
Integrate equipment acceptance, change control and management review. 整合設備准入、變更控制及管理審查。 |
Performance dashboard, internal review and management decisions 績效儀表板、內部查核及管理決策 |
Investment should prioritize measures that directly reduce significant risks, such as protective fixtures, independent shutdown functions, effective extraction and handling aids. Reliable budgets require equipment quantities, site conditions and supplier quotations.
投資應優先配置於直接降低重大風險的措施,例如防護治具、獨立停機功能、有效排氣及搬運輔具。可靠預算須以設備數量、現場條件及供應商報價為基礎。
Chapter 15. Conclusions and Further Investigation
第十五章 結論與後續調查
An effective IC design safety program should follow the research and development process. Ergonomics and workload management belong in project planning; electrical, thermal and chemical protection belong in laboratory design and test development.
有效的 IC 設計職安衛制度,應配合研發流程建立。人因與工作負荷管理應納入專案規劃;電氣、熱及化學防護則應納入實驗室設計與測試開發。
The quality of the program depends on evidence that controls work in practice. Procedures and training records alone do not demonstrate that an interlock stops a hazardous test, extraction captures emissions or a workload intervention provides adequate recovery.
制度品質取決於控制措施實際有效的證據。僅有程序與訓練紀錄,不能證明連鎖能停止危險測試、排氣能捕集污染物,或工作負荷改善能提供足夠休息。
Company-specific implementation should begin with workforce information, site layouts, equipment and chemical inventories, working patterns and existing management records. These inputs support a defensible determination of legal applicability, improvement priorities and budget.
公司實際導入應先取得人數、場域配置、設備與化學品清冊、工作型態及既有管理紀錄,據以合理判定法規適用性、改善優先序及預算。
References
參考資料
[1] Taiwan Ministry of Justice — Occupational Safety and Health Act
法務部全國法規資料庫——職業安全衛生法
https://law.moj.gov.tw/LawClass/LawAll.aspx?PCode=N0060001
[2] Taiwan Occupational Safety and Health Administration — Explanation and Implementation Plan for the Amended Occupational Safety and Health Act
勞動部職業安全衛生署——新修職安法整體說明及施行規劃
https://www.osha.gov.tw/48110/48713/207079/207115/207278/post
[3] Taiwan Occupational Safety and Health Administration — Guidelines for Prevention of Diseases Induced by Abnormal Workload, Second Edition
勞動部職業安全衛生署——異常工作負荷促發疾病預防指引(第二版)
https://www.osha.gov.tw/48110/48713/48735/60211/
[4] Taiwan Occupational Safety and Health Administration — Ergonomic Hazard Prevention Program Guidelines
勞動部職業安全衛生署——人因性危害預防計畫指引
https://www.osha.gov.tw/48110/48713/48735/60198/post
[5] Taiwan Ministry of Labor — Occupational Safety and Health Facilities Regulations, Article 254
勞動部——職業安全衛生設施規則第 254 條
https://laws.mol.gov.tw/flaw/FLAWDOC01.aspx?flno=254&id=FL015021
[6] U.S. Occupational Safety and Health Administration — Semiconductors: Electricity
美國職業安全衛生署——半導體電氣安全
https://www.osha.gov/semiconductors/solutions/electricity
[7] UK Health and Safety Executive — Solderer
英國健康與安全執行署——焊接作業與焊煙危害預防
https://www.hse.gov.uk/asthma/solderers.htm